FLB/TLB-2x-Scope V1.0 (KW 09/2006 - 03.03.2006) 6
pc_file_name:
This info field displays the currently selected file name of the
output file with the corresponding directory path.
The current parameters are stored (SEND button) or retrieved
(GET button) in or from the output file displayed here.
If another output file should be accessed, the file button must first be activated with the mouse pointer. Then another
dialog field will open, where an existing output file can be selected, or where a file name for a new output file can be
entered.
LASMOD setting:
In this function group the laser operating mode and the laser power can be adjusted at the
sensor that is connected to the electronic control unit.
STAT:
With this selection button the laser power is constantly kept at the value that is set at the slider.
DYN:
The laser power is automatically and dynamically adjusted by means of the amount of
radiation reflected from the object. By way of dynamic adaptation of the laser power the µC-
software tries to keep the current maximum value that is detected at the receiver in the range
of 100 to 200 A/D-values. In this operating mode the POWER slider is ineffective.
POWER:
With this slider the laser power is adjusted to a fixed value between 0 and 255 in STAT mode.
Any change only becomes effective after the SEND button is pressed.