FLB/TLB-2x-Scope V1.0 (KW 09/2006 - 03.03.2006) 4
The function of the individual FLB-CON2-2X control elements will be explained
on the following pages:
REF1 and TOL1 setting:
Entering a value in the REF1 edit-box teaches the reference for the first
window.
Entering a value in the TOL1 edit-box applies a ±tolerance around this
value.
REF2 and TOL2 setting:
Entering a value in the REF2 edit-box teaches the reference for the second
window.
Entering a value in the TOL2 edit-box applies a ±tolerance around this
value.
DYN_LO and DYN_HI:
The two function fields DYN_LO and DYN_HI are used for setting a
lower and higher dynamic range limit for the sensor. When the sensor is
within the dynamic range (DYN-LO < DATA < DYN-HI), the dynamic
check output (green LED at the sensor housing) is active.
HYST:
The hysteresis setting value lies below or above the current reference
window (REF1 ± TOL1, REF2 ± TOL2). The switching hysteresis affects
the corresponding digital output. It increases the signal stability at the
digital output of the electronic control unit FLB-CON2-2X.
POLARITY:
Determines the polarity change of the digital outputs when the value rises
above or falls below the respective thresholds.
AVERAGE:
Determines the number of measured values (raw data) over which the
sensor signal arriving at the receiver is averaged (noise suppression).