RS-232/UART specifications and characteristics
UART protocols supported RS-232
RS-422 up to 10 Mbp/s, differential probing recommended.
RS-485 up to 10 Mbp/s, differential probing recommended.
Other UART interfaces which admit to user-specified parameters
available in the application.
The application relies on probing and trigger/measurement thresholds
to properly condition the signal for triggering and decode.
The Infiniium 90000 Series requires E2697A hi-pod adapters for probes
with 1 MΩ impedance.
Tx and Rx source Analog channels 1, 2, 3, or 4
Any waveform memory
Auto setup Automatically configures trigger levels, measurement thresholds, memory depth, sample
rate, trigger and holdoff for proper decode and triggering.
Decode word size User-selectable: 5, 6, 7, 8, or 9 bits
Parity: odd, even, none
Decode bit order User-selectable: LSB or MSB
Supported baud rates User selectable: 1.2 kb/s up to 10 Mb/s
Idle Polarity User selectable: low or high
Triggering
(software-based)
User selectable: transmit or receive
User selectable data length: 1 to 13 words (each word takes 2 trigger symbols)
Word size selectable from 5 to 9 bits
Enter trigger in HEX, binary, decimal or ASCII